ETO Sterilize

ETO Sterilize
ETO Sterilize

ETO Sterilize Specification

  • Type
  • Automatic / Semi-automatic
  • Chamber Size
  • 900 x 1100 x 1800 mm
  • Chamber Thickness
  • 5 mm
  • Outer Size
  • 1450 x 1700 x 2500 mm
  • Compressed Air
  • 6 bar
  • Door Type
  • Single or Double Hinged
  • Design Pressure
  • 1.2 kg/cm
  • Working Pressure
  • 0.9 kg/cm
  • Design Temperature
  • 80C
  • Heat Uniform
  • 2.5C
  • Insulation
  • 50 mm PUF / Glass Wool
  • Net Weight
  • 1200 kg (approx.)
  • Recording Parameters
  • Digital / Printer / USB
  • Spraying Mode
  • Atomized ETO + Steam / Water
  • Outer Trolley
  • Available
  • Inner Trolley
  • Available
  • Spraying Piping
  • SS 316L
  • Steam
  • 2.0 to 2.5 bar
  • Sterilizing Temperature
  • 37C to 60C
  • Working Temperature
  • 50C (Max)
  • Sterilization Time
  • 1 to 6 hours
  • Temperature Scope
  • Room temperature to 60C
  • Piping System
  • SS316/316L with tri-clover joints
  • Valves
  • SS 316
  • Power Consumption
  • 4 KW
 

ETO Sterilize Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 3 Pieces Per Week
  • Delivery Time
  • 4 Months
 

About ETO Sterilize

ETO Sterilize machine manufactured and supplied by our company is specially designed for the sterilization of elements that show high incompatibility with steam. It is designed and developed by using advanced technologies that result in high working efficiency and robustness. The in-built control panel of this machine makes it easier for a single user to operate it. Get ETO Sterilize as per your demands with a supply ability of 3 units per week.


Superior Build and Safety Mechanisms

Engineered with a corrosion-resistant SS 316L mirror-finish chamber and double silicone gaskets, the ETO Sterilizer guarantees longevity and a consistent airtight seal. Multi-level safety interlocks at the door, pressure, and cycle phases minimize risk, while audio-visual alarms provide immediate alerts for added assurance during operation.


Intelligent Control and Enhanced Usability

The integration of a PLC with a touchscreen interface delivers intuitive control, supporting standard, custom, and emergency sterilization cycles. Real-time digital readouts of temperature, pressure, and cycle status improve user oversight. Automated gas inlet systems, digital/USB data recording, and catalytically converted exhausts streamline processes and maintain user convenience.


Validated, Efficient Sterilization Process

This sterilizer is designed for precise and repeatable sterilization, with validation ports to support biological and chemical indicator testing. High vacuum pump efficiency and atomized ETO plus steam/water spraying guarantee uniform gas distribution. The system accommodates various loads and trolleys, helping facilities meet stringent sterility requirements with every cycle.

FAQs of ETO Sterilize:


Q: How does the ETO Sterilizer ensure consistent sterilization results?

A: The ETO Sterilizer utilizes a high-efficiency 250 LPM vacuum pump and atomized ETO with steam/water spraying to guarantee uniform gas distribution within the chamber. It is equipped with a PLC-controlled process, maintaining precise temperature (2.5C) and adjustable sterilization times (16 hours), ensuring every cycle delivers reliable sterility.

Q: What safety features are incorporated in this ETO Sterilizer?

A: This unit features multi-level safety interlocks linked to the door, pressure, and cycle phases, as well as a robust audio-visual alarm system. These mechanisms prevent unauthorized access and promptly warn operators of unsafe conditions, enhancing operator and workspace safety during use.

Q: When should the validation port be used during the sterilization cycle?

A: The validation port is intended for the placement of biological or chemical indicators before running a cycle. It allows for direct verification of sterilization efficacy and should be accessed at the start of each batch or whenever regulatory compliance testing is required.

Q: Where is the ETO Sterilizer typically installed and what are its installation requirements?

A: Designed for floor mounting, the sterilizer is appropriate for hospital CSSDs, pharmaceutical manufacturers, and laboratory settings. It requires a stable 415V, 50Hz, 3-phase power supply, 6 bar compressed air, and appropriate steam and exhaust connections. Dimensions and weight should be considered for the installation area.

Q: What is the process for selecting different cycle modes on this sterilizer?

A: Operators can select standard, custom, or emergency cycles via the PLC touchscreen. Parameters such as temperature, time, and pressure can be adjusted to suit specific sterilization requirements, providing flexibility for different loads and urgency levels.

Q: How is the data from sterilization cycles recorded for documentation or audits?

A: All cycle parameters are digitally recorded and can be accessed via the onboard printer or transferred through a USB interface. This ensures thorough documentation of each process for compliance and traceability.

Q: What are the key benefits of using the SS 316L mirror-finish chamber material?

A: SS 316L offers exceptional corrosion resistance, smooth surface hygiene, and robust mechanical strength. The mirror finish supports easy cleaning and reduces contamination risk, making it ideal for strict sterilization environments.